MAC 5500 Portable ECG EKG Diagnosis System
Built on GE’s proven innovation in ECG
acquisition and analysis, the MAC® 5500
is
GE’s premier ECG system, delivering
advanced disease management capabilities
through its industry-leading collection
of standards-setting algorithms and
advanced
networking.
The MAC 5500 system offers the
sophistication required for advanced ECG
applications,
while its ease of use extends this level
of performance to the broadest
range of users possible. And, it’s part
of the complete GE suite of networked,
non-invasive testing solutions designed
to maximize efficiency and productivity
in hospitals, clinics, office based practices and research institutes.
• 12-/15-Lead High-End ECG System for
Resting-ECG’s and Stress-Test
• Easy-to-use applications and features
streamline productivity and workflow
• Advanced algorithms set the standard
in ECG analysis and interpretation
• Improving Clinical Trial Workflow with
CT Data Guard
• Multiple Network Capabilities
(Ethernet and wireless)
• Internal Modem
• Barcode and magnetic card scanning
options
• XML data export capabilities
• Internal Memory for 200 ECG’s, SD-card
removable Media
• Easy updating via Optioncodes
• Seamless connectivity to the MUSE®
cardiology information system speeds
data storage and ECG retrieval
One of the most complete suite of
analysis algorithms for
advanced ECG applications.
The MAC 5500 system offers a
comprehensive suite of ECG
interpretation and
clinically validated analysis programs.
Its array of arrhythmia and chest pain
tools allow you to address a wider range
of disease management needs. Make
more efficient treatment decisions. And
use invasive tests more judiciously.
Our Marquette® ECG analysis programs are
the preferred choice in a variety of
care settings and industries, including
hospitals, clinics, physician offices
and
clinical research organizations (CROs).
• Marquette 12SLTM
ECG analysis program
for adults and pediatrics – the
industry’s most thoroughly documented,
simultaneous 12-lead ECG acquisition
analysis program for uncompromising
quality and reliability – remains your
most clinically valuable second opinion.
• Marquette 12SL with Gender-Specific
interpretation features criteria
that
help you more easily detect acute
myocardial infarction (MI) in female
patients,
enhancing diagnostic confidence even
among occasional readers of ECGs.
• Simultaneous 15-lead acquisition,
storage, and assessment provides
additional ST measurements for the
detection of changes that occur in
some non-diagnostic 12-lead cases to
facilitate the prompt detection
of right ventricular and posterior MI.
MAC 5500 at a glance
Gender-Specific Criteria Enhancement
Utilizing unique clinically correlated
criteria for
evaluating the ST segment and T-wave for
the
ECG waveform, GE 12SL Gender-Specific
interpretive
software assists clinicians in detecting
acute
MIs in female patients and enhances
diagnostic
confidence among even occasional ECG
readers.
• Marquette 12SL with ACI-TIPI
(Acute Cardiac Ischemia Time-Insensitive
Predictive Instrument) considers a
patient’s age, gender, and chief
complaint, as
well as ECG measurements, to generate a
numerical score that helps predict the
probability of acute cardiac ischemia.
This optional program provides important
additional triage information for
patients with chest pain.
• P-Wave Signal Averaging option
for atrial arrhythmia assessment
features a
patented templating algorithm that
enhances P-wave measurement accuracy.
• Hi-Res Late Potential Analysis
option supports effective ventricular
arrhythmia
assessment, with an intuitive design
that creates a practical, non-invasive
alternative to involved invasive
testing.
• Enhanced Pacemaker-Detection
Software improves sensitivity to
electronically
paced hearts.
• Vectorcardiography
• Marquette Hookup AdvisorTM
signal quality analysis program reviews
and
measures ECG waveforms for signs of
artifact and interference, helping to
eliminate poor waveform quality during
the recording of ECGs.
• Serial ECG Comparisons, through
the MUSE cardiology information system,
leverages the Marquette 12SL ECG
analysis program and analyzes both
short- and long-term changes in
patients’ ECGs.
Innovative features streamline workflow
and expand your
capabilities.
Specifically designed to enhance your
entire staff’s efficiency, the MAC 5500
system combines technological advances
with ease-of-use features in one
system.
• Digital CAM-14 module reduces noise
and artifact for clearer ECG tracings.
• Large field-of-view display provides a
clear view of the screen from any angle.
• Analog ECG output facilitates easy
integration with other
cardiac-diagnostic
devices, such as echocardiography and
nuclear medicine systems.
• Extensive customization – including
display and final-report formatting –accommodates individual user
preferences.
• Stress option incorporates leading
exercise-testing technologies.
Signal acquisition
advances help reduce baseline wander and
ST-segment distortion
to generate clearer, more defined ECGs.
• Barcode and magnetic card reader
options help reduce errors by automating
the input of patient data.
• Security protocols and
user-configurable password protection
provides security
to assist you in addressing HIPAA
requirements.
• Trolley design features a convenient
holder for the acquisition module, ample
writing surface area, wide bins, and a
covered storage compartment.
• Compact system design offers easy
mobility.
Marquette Hookup AdvisorTM signal
quality analysis program
Digital CAM-14 module
Barcode and magnetic card reader.
The sinal-averaged high-resolution
P wave (PHi-Res) analysis performs
signal averaging of P waves using a
P wave trigger and provides filtering
and delineation of the averaged
P-wave.
Modem
Taking ECG workflow to the next level.
Full connectivity allows you to tap into
the power of GE’s cardiology information
system MUSE – for streamlined workflow
and higher functionality. Networked
access delivers improved efficiency and
decision support.
• Access the computer ECG patient
records immediately, any time of day or
night,
using the Remote Query option for more
responsive patient care.
• Optional Ethernet and MobileLinkTM
wireless capabilities permit
bi-directional
communication with the MUSE system. You
can quickly retrieve, manage, and
archive patient data – and reduce the
potential for errors. Also helps meet
ACC/
AHA guidelines for time-to-cardiologist
overread and time-to-treatment goals.
• Instantly access procedure requests
and download patient demographic
data from the Hospital Information
System through the MUSE system. This
functionality reduces time-consuming
patient data entry and minimizes
delays in procedure billing.
• Access ECG records from the clinic,
office, or other remote facility using a
standard modem for maximum
decision-making efficiency.
• Secure digital memory card facilitates
external archive capabilities and easy
updating.
• Export and archive data in XML format
for flexible, open communications.
MAC 5500 for CRO requirements
• 4 user-definable fields for
patient data entry flexibility.
• Optional CT (Clinical Trial) data
guard feature is designed
to help guarantee the integrity of the
digital ECG record,
support of 21 CFR Part 11 compliant
workflow, enhance
security and protect electronic records.
Easier regulatory compliance
Requiring minimal policies and
procedures to meet compliancy,
MAC 5500 with optional CT Data Guard –
coupled with
the complete functionality of the MUSE –
gives clinical research
organizations (CROs) an advantage when
linked with minimal
standard operating procedures created by
the organization.
GE MAC 5500 ECG Cables and Leadwires:▼...
..

ECG
Cables and Leadwires
2016560-003
Patient cable coiled to
CAM 14 Module MAC
5500ST, 4,6 m |

420101-001 Lead Wire MultiLink
Universal, Mixed length, 14/set
420101-002
10/set |

2001925-002 Lead wire MultiLink
Universal, 74 cm 2001925-004 Lead
wire MultiLink Universal, 130 cm |

GE Marquette Mac 5500 ECG 900178-101
Set Connector Banana 4mm, 10 pcs.,
IEC 900178-201 14 pcs., IEC |
GE MAC 5500 ECG Electrode for Resting ECG:▼...
..

ge marquette mac 5500 ekg ecg
machine 21714401Chest suction
electrode, Silver/Silver Chloride,
22 cm diam. 21714402 (C6) only |

ge marquette mac 5500 ekg ecg
machine 91920232 Set Clamp
electrodes Adult/pediatric for limb
leads, reusable, Set/4 |

ge marquette mac 5500 ekg ecg
machine 9623-003P Tab- electrode
Silver Mactrode Plus, Silver/ Silver
Chloride, 1000 pcs. 9623-103P 1400
pcs. |

ge marquette mac 5500 ekg ecg
machine 402207-210 BabyMac
disposable infant Resting ECG
electrodes, 500 pcs/case |

ge marquette mac 5500 ekg ecg
machine 2014777-001 SILVERTRACE
ELECTRODE P55MO Adult ROUND 300/CASE |
|
|
|
GE MAC 5500 ECG
Adapters: ▼

ge marquette mac 5500 ekg ecg
machine 9490-105 Set Adapter
Grey/Black Alligator/Banana socket
4mm, 10/set |

ge marquette mac 5500 ekg ecg
machine 9490-210 Adapter for
tab-electrodes, 10 pcs. |
|
|
G E MAC 5500
Electrode for Stress ECG:▼...
.

ge marquette mac 5500 ekg ecg
machine 900703-230 SilverTrace
disposable electrode adult, oval,
foam, wet gel, 300 pcs 900703-205
SilverTrace Adult Stress Electrode,
foam oval, wet gel, 600/case |

ge marquette mac 5500 ekg ecg
machine 9653-305 SilverTrace Adult
Holter/Stress Electrode, Vinyl tape
round, solid gel, 300/case |

ge marquette mac 5500 ekg ecg
machine 2014768-001 SILVERTRACE
ELECTRODES MULTI P21MO FOAM OVAL
W/TAB 300/CASE |
|
|